{"id":2914,"date":"2026-03-13T14:10:56","date_gmt":"2026-03-13T13:10:56","guid":{"rendered":"https:\/\/test.ibib.waw.pl\/?page_id=2914"},"modified":"2026-04-02T09:37:42","modified_gmt":"2026-04-02T07:37:42","slug":"system-ciaglego-monitorowania-plynow-drenazowych-do-oceny-postepow-leczenia-chorych-z-wtornym-bakteryjnym-zapaleniem-otrzewnej","status":"publish","type":"page","link":"https:\/\/ibib.waw.pl\/en\/nauka\/projekty\/projekty-realizowane-w-ibib-pan-archiwum\/system-ciaglego-monitorowania-plynow-drenazowych-do-oceny-postepow-leczenia-chorych-z-wtornym-bakteryjnym-zapaleniem-otrzewnej\/","title":{"rendered":"Continuous Monitoring System for Drainage Fluids for the Assessment of Treatment Progress in Patients with Secondary Bacterial Peritonitis"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\"><strong>Cel projektu<\/strong><\/h3>\n\n\n\n<p>Opracowanie innowacyjnego, miniaturowego czujnika pH, zintegrowanego z drenem, umo\u017cliwiaj\u0105cego ci\u0105g\u0142\u0105 ocen\u0119 post\u0119p\u00f3w leczenia pacjent\u00f3w z wt\u00f3rnym zapaleniem otrzewnej (WZO).<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Znaczenie problemu<\/strong><\/h3>\n\n\n\n<p>Otrzewna to najwi\u0119ksza b\u0142ona surowicza w organizmie cz\u0142owieka, wy\u015bcielaj\u0105ca jam\u0119 brzuszn\u0105 oraz jam\u0119 miednicy. Stan zapalny otrzewnej powstaje w wyniku przedostania si\u0119 bakterii lub niezaka\u017conego p\u0142ynu ustrojowego do jamy otrzewnej. Najcz\u0119stszym rodzajem zapalenia otrzewnej jest wt\u00f3rne, bakteryjne zapalenie otrzewnej (WZO), kt\u00f3re zazwyczaj jest wynikiem perforacji przewodu pokarmowego. Rocznie, w Polsce wt\u00f3rne, bakteryjne zapalenie otrzewnej rozwija si\u0119 u 180\/100 000 os\u00f3b. WZO wymaga leczenia chirurgicznego i farmakologicznego, jednak pomimo znacznego post\u0119pu w zakresie farmakoterapii i chirurgii, choroba ta charakteryzuje si\u0119 wysok\u0105 \u015bmiertelno\u015bci\u0105 w okresie oko\u0142ooperacyjnym. Aby temu zapobiec, kluczowe jest wczesne rozpoznanie WZO i zastosowanie odpowiedniej terapii. Monitorowanie p\u0142yn\u00f3w drena\u017cowych jest jednym z element\u00f3w oceny skuteczno\u015bci terapii i umo\u017cliwia wczesn\u0105 identyfikacj\u0119 rozwijaj\u0105cych si\u0119 powik\u0142a\u0144. Co prawda, monitorowanie pH p\u0142ynu drena\u017cowego pacjent\u00f3w z WZO nie jest obecnie standardem medycznym, jednak\u017ce mo\u017ce by\u0107 u\u017cytecznym parametrem stosowanym do oceny post\u0119p\u00f3w leczenia. Nag\u0142e zmiany pH mog\u0105 wskazywa\u0107 m.in.: na rozw\u00f3j powik\u0142a\u0144 lub by\u0107 wczesnym markerem nieszczelno\u015bci zespolenia. W ramach Projektu zostanie opracowane narz\u0119dzie do pomiaru pH, zintegrowane z systemem drena\u017cu do ci\u0105g\u0142ego monitorowania st\u0119\u017cenia jon\u00f3w H+ w p\u0142ynach drena\u017cowych pacjent\u00f3w. Monitorowanie pH w czasie rzeczywistym u\u0142atwi ocen\u0119 post\u0119p\u00f3w leczenia i umo\u017cliwi szybk\u0105 reakcj\u0119 w przypadku zmiany tego parametru, na skutek pogorszenia stanu zdrowia pacjent\u00f3w.<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Cechy miniaturowych czujnik\u00f3w pH:<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Wysoka stabilno\u015b\u0107 pracy<\/li>\n\n\n\n<li>Wysoka czu\u0142o\u015b\u0107<\/li>\n\n\n\n<li>Brak ciek\u0142ego elektrolitu \u2192 miniaturyzacja<\/li>\n\n\n\n<li>Wytworzone technik\u0105 druku bezpo\u015bredniego<\/li>\n<\/ul>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Potencjalne korzy\u015bci kliniczne<\/strong><\/h3>\n\n\n\n<ul class=\"wp-block-list\">\n<li>Dodatkowy parametr wspieraj\u0105cy decyzje terapeutyczne<\/li>\n\n\n\n<li>Poprawa skuteczno\u015bci leczenia WZO<\/li>\n\n\n\n<li>Mo\u017cliwo\u015b\u0107 wykrywania nieszczelno\u015bci zespolenia przewodu pokarmowego<\/li>\n<\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"975\" height=\"1024\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-975x1024.png\" alt=\"\" class=\"wp-image-2924\"\/><\/figure>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Zesp\u00f3\u0142 badawczo-rozwojowy<\/strong><\/h3>\n\n\n\n<p>Kierownik projektu: dr in\u017c. Marcin Urbanowicz (IBIB PAN)&nbsp;<\/p>\n\n\n\n<p>Technolog chemiczny: dr in\u017c. Agnieszka Paziewska-Nowak (IBIB PAN)<\/p>\n\n\n\n<p>Technolog druku bezpo\u015bredniego: dr in\u017c. Marek Dawgul (IBIB PAN)<\/p>\n\n\n\n<p>Elektrochemik: mgr Kornelia Bobrowska (IBIB PAN)<\/p>\n\n\n\n<p>Chemik analityk: mgr in\u017c. Anna So\u0142datowska (IBIB PAN)<\/p>\n\n\n\n<p>Konsultant ds. medycznych: dr n. med. Marcin Ekman (UCK Gda\u0144sk) [<a href=\"https:\/\/ppm.gumed.edu.pl\/info\/author\/GUM0aed504c286c4a20a7f44658b31eddb5\/\" target=\"_blank\" rel=\"noreferrer noopener\">LINK do BIO<\/a>]<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Personel pomocniczy<\/strong><\/h3>\n\n\n\n<p>Biolog: dr Krzysztof Pluta (IBIB PAN)<\/p>\n\n\n\n<p>Biotechnolog: mgr Monika Wi\u015bniewska (IBIB PAN)<\/p>\n\n\n\n<p>Pomocnik ds. eksperyment\u00f3w SPR: in\u017c. Maria Baczy\u0144ska (studentka Politechniki Warszawskiej, kierunek Biotechnologia II stopie\u0144, specjalno\u015b\u0107 Biotechnologia Medyczna)<\/p>\n\n\n\n<p>Pomocnik ds. technologicznych: in\u017c. Gabriela Krasiejko (studentka Politechniki Warszawskiej, kierunek In\u017cynieria Chemiczna i Procesowa II stopie\u0144, specjalno\u015b\u0107 &#8211; In\u017cynieria Proces\u00f3w Przemys\u0142owych)<\/p>\n\n\n\n<p>Pomocnik ds. medycznych: Katarzyna Po\u0142omska (studentka Gda\u0144skiego Uniwersytetu Medycznego w Gda\u0144sku, kierunek lekarski)<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Doradztwo naukowe<\/strong><\/h3>\n\n\n\n<p>prof. dr hab. in\u017c. Dorota G. Pijanowska (IBIB PAN) (IBIB PAN)<\/p>\n\n\n\n<p>prof. dr hab. n. med. Jaros\u0142aw Kobiela (Gda\u0144ski Uniwersytet Medyczny) [https:\/\/ppm.gumed.edu.pl\/info\/author\/GUM879397daddeb4ed1af19eecfbc490e9b\/]<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Finansowanie<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Projekt finansowany przez Agencj\u0119 Bada\u0144 Medycznych w ramach Rz\u0105dowego Planu Rozwoju Sektora Biomedycznego na lata 2022\u20132031 na kwot\u0119 4 815 100 PLN.<br><br>Nr umowy: KPOD.07.07-IW.07-0115\/24.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1018\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-1-1024x1018.png\" alt=\"\" class=\"wp-image-2925 size-full\"\/><\/figure><\/div>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Nawi\u0105zane wsp\u00f3\u0142prace<\/strong><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Katedra i Klinika Chirurgii Onkologicznej Transplantacyjnej i Og\u00f3lnej, Uniwersyteckie Centrum Kliniczne w Gda\u0144sku. <\/li>\n\n\n\n<li>Wydzia\u0142 Elektroniki, Fotoniki i Mikrosystem\u00f3w, Politechnika Wroc\u0142awska<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Patenty<\/strong><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Zg\u0142oszenie Patentowe: M. Urbanowicz, M. Dawgul, D. G. Pijanowska; Planarna mikroelektroda jonoselektwyna oraz spos\u00f3b jej wykonania. P.448894 [WIPO ST 10\/C PL448894] (2024)<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Artyku\u0142y naukowe:<\/strong><\/h3>\n\n\n\n<p>A. Paziewska-Nowak, M. Urbanowicz, M. Dawgul, K. Bobrowska, A. So\u0142datowska, M. Ekman, D. G. Pijanowska,&nbsp;<em>Highly stable direct-printed polyazulene-based miniaturized electrode for pH analysis in human body fluid,&nbsp;<\/em>Biocybernetics and Biomedical Engineering, 46, 2026, 40-49&nbsp;<a href=\"https:\/\/doi.org\/10.1016\/j.bbe.2025.11.008\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.bbe.2025.11.008<\/a>&nbsp;IF: 6.6<\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Konferencje:<\/strong><\/h3>\n\n\n\n<ol class=\"wp-block-list\">\n<li>M. Urbanowicz, A. Paziewska-Nowak, K. Bobrowska, A. So\u0142datowska, M. Dawgul, M. Ekman, D.G. Pijanowska, Direct-printed, solid-contact pH sensor for clinical applications: Challenges of non-specific adsorption, EUROSENSORS XXXVII, September 07-10 2025, Wroc\u0142aw, https:\/\/www.ama-science.org\/proceedings\/getFile\/AwZ3AN<\/li>\n\n\n\n<li>M. Urbanowicz, M. Dawgul, A. Paziewska-Nowak, K. Bobrowska, A. So\u0142datowska, D.G. Pijanowska, Direct printed potentiometric sensors for pH monitoring in body fluids, NBC 2025 &amp; PCBBE 2025 &#8211; Joint 20th Nordic-Baltic Conference on Biomedical Engineering &amp; 24th Polish Conference on Biocybernetics and Biomedical Engineering, June 16-18 2025, Warszawa<\/li>\n<\/ol>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Rozw\u00f3j naukowy m\u0142odej kadry<\/strong><\/h3>\n\n\n\n<p>Prace magisterskie:<\/p>\n\n\n\n<ol class=\"wp-block-list\">\n<li>Badanie funkcjonalizowanych elektrod wykonanych technik\u0105 druku bezpo\u015bredniego do konstrukcji potencjometrycznego bioczujnika mocznika, dyplomantka: in\u017c. Maria Baczy\u0144ska, Promotor: dr hab. in\u017c. \u0141ukasz G\u00f3rski, Opiekun naukowy: dr in\u017c. Marcin Urbanowicz<\/li>\n\n\n\n<li>Charakterystyka elektrochemiczna uk\u0142ad\u00f3w elektrodowych wykonanych technik\u0105 druku bezpo\u015bredniego jako pod\u0142o\u017ca czujnik\u00f3w selektywnych na jony potasu, dyplomantka: in\u017c. Gabriela Krasiejko, Promotor: dr in\u017c. Zuzanna Bojarska, Opiekun naukowy: dr in\u017c. Marek Dawgul<\/li>\n<\/ol>\n\n\n\n<h2 class=\"wp-block-heading\"><strong>Aktualno\u015bci<\/strong><\/h2>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Marzec 2026\u00a0<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading has-text-align-center\"><strong><strong>Targi<strong> LABS EXPO 2026<\/strong><\/strong><\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Rezultaty naszego projektu zosta\u0142y przedstawione podczas targ\u00f3w <strong>LABS EXPO 2026<\/strong>, kt\u00f3re odby\u0142y si\u0119 <strong>18\u201319 marca 2026 r. w Poznaniu<\/strong>. Wydarzenie by\u0142o okazj\u0105 do zaprezentowania za\u0142o\u017ce\u0144 naszego projektu oraz potencja\u0142u opracowywanego rozwi\u0105zania dla potrzeb klinicznych monitorowania pH w p\u0142ynach drena\u017cowych. Obecno\u015b\u0107 na targach umo\u017cliwi\u0142a r\u00f3wnie\u017c promocj\u0119 projektu oraz wymian\u0119 do\u015bwiadcze\u0144 z przedstawicielami \u015brodowiska naukowego i otoczenia komercyjnego.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"697\" height=\"665\" src=\"http:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/04\/image.png\" alt=\"\" class=\"wp-image-3175 size-full\"\/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Luty 2026&nbsp;<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading has-text-align-center\"><strong>Nowa celka przep\u0142ywowa dedykowana miniaturowym czujnikom pH opracowanym w IBIB PAN<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>W ramach realizacji projektu zako\u0144czono prace dotycz\u0105ce opracowania serii celek przep\u0142ywowych wykonanych w technologii druku 3D (Material Jetting), umo\u017cliwiaj\u0105cych integracj\u0119 opracowanych w IBIB PAN miniaturowych czujnik\u00f3w pH z systemem drena\u017cu oraz prowadzenie bada\u0144 w warunkach przep\u0142ywu pr\u00f3bki. Celka zosta\u0142a opracowana we wsp\u00f3\u0142pracy z dr in\u017c. Wojciechem Kubickim (Politechnika Wroc\u0142awska), kt\u00f3ry w ramach wizyty w IBIB PAN wyg\u0142osi\u0142 seminarium na temat rozwi\u0105za\u0144 konstrukcyjnych zwi\u0105zanych z uk\u0142adami mikrofluidycznymi oraz drukiem 3D i ich zastosowaniem w badaniach<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"715\" height=\"459\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-2.png\" alt=\"\" class=\"wp-image-2928 size-full\"\/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Stycze\u0144 2026<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Rozbudowa infrastruktury badawczej IBIB PAN dzi\u0119ki finansowaniu z ABM<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>W ramach realizacji projektu zaplecze aparaturowe IBIB PAN zosta\u0142o rozbudowane o nowoczesny system do pomiar\u00f3w technik\u0105 rezonansu plazmon\u00f3w powierzchniowych (SPR). Jest to pierwszy w Polsce system Octet\u00ae SF3, a jednocze\u015bnie jeden z siedmiu system\u00f3w dost\u0119pnych w Europie. Wdro\u017cenie tej aparatury stanowi istotny skok naprz\u00f3d w prowadzonych badaniach, umo\u017cliwiaj\u0105c bezznacznikow\u0105 analiz\u0119 oddzia\u0142ywa\u0144 molekularnych w czasie rzeczywistym, w tym ocen\u0119 niespecyficznych interakcji sk\u0142adnik\u00f3w p\u0142yn\u00f3w drena\u017cowych z powierzchniami czujnikowymi.<br>Unikatowo\u015b\u0107 aparatury wynika z zastosowania zaawansowanych rozwi\u0105za\u0144, takich jak mo\u017cliwo\u015b\u0107 prowadzenia pomiar\u00f3w w gradiencie st\u0119\u017ce\u0144, pozwalaj\u0105cych na wyznaczenie parametr\u00f3w kinetycznych oraz powinowactwa w trakcie jednej iniekcji pr\u00f3bki. Rozwi\u0105zanie to znacz\u0105co skraca czas eksperyment\u00f3w, ogranicza zu\u017cycie pr\u00f3bek oraz minimalizuje ryzyko b\u0142\u0119d\u00f3w przygotowawczych. Dodatkowo, aparatura umo\u017cliwia pe\u0142n\u0105 automatyzacj\u0119 pomiar\u00f3w, zapewniaj\u0105c wysok\u0105 stabilno\u015b\u0107 sygna\u0142u, co jest szczeg\u00f3lnie istotne podczas bada\u0144 z wykorzystaniem pr\u00f3bek biologicznych o z\u0142o\u017conej matrycy. Aparatura znajdzie r\u00f3wnie\u017c szerokie zastosowanie w przysz\u0142ych badaniach nad rozwojem nowych bioczujnik\u00f3w przeznaczonych do zastosowa\u0144 klinicznych.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"881\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-4-1024x881.png\" alt=\"\" class=\"wp-image-2931 size-full\"\/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Grudzie\u0144 2025<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Kolejny krok ku zastosowaniom klinicznym \u2013 testy z p\u0142ynami drena\u017cowymi pacjent\u00f3w i publikacja w czasopi\u015bmie Biocybernetics and Biomedical Engineering<\/strong>&nbsp;<\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Nasze rezultaty prac badawczych uzyskane w ramach projektu zosta\u0142y opublikowane w renomowanym czasopi\u015bmie naukowym indeksowanym w bazie JCR, wed\u0142ug ASJC kategoria &#8211; in\u017cynieria biomedyczna, I-szy kwartyl i 92 percentyl. A. Paziewska-Nowak, M. Urbanowicz, M. Dawgul, K. Bobrowska, A. So\u0142datowska, M. Ekman, D. G. Pijanowska,&nbsp;<em>Highly stable direct-printed polyazulene-based miniaturized electrode for pH analysis in human body fluid<\/em>,&nbsp;<strong>Biocybernetics and Biomedical Engineering<\/strong>, 46,&nbsp;<strong>2026<\/strong>, 40-49 IF: 6.6, Liczba punkt\u00f3w ministerialnych: 140&nbsp;<a href=\"https:\/\/doi.org\/10.1016\/j.bbe.2025.11.008\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/doi.org\/10.1016\/j.bbe.2025.11.008<\/a><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"738\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-5-1024x738.png\" alt=\"\" class=\"wp-image-2932 size-full\"\/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>W ramach wsp\u00f3\u0142pracy z Gda\u0144skim Uniwersytetem Medycznym (nr umowy 13\/ZP\/2025) do IBIB PAN dostarczono pr\u00f3bki p\u0142yn\u00f3w drena\u017cowych od pacjent\u00f3w leczonych z powodu wt\u00f3rnego zapalenia otrzewnej. Dzi\u0119ki temu rozpocz\u0119to testy opracowanych czujnik\u00f3w pH z wykorzystaniem materia\u0142u biologicznego pobranego od pacjent\u00f3w&nbsp;<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"768\" height=\"1024\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-6-768x1024.png\" alt=\"\" class=\"wp-image-2934 size-full\"\/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Listopad 2025<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Testy czujnik\u00f3w pH w warunkach przep\u0142ywowych<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Opracowany czujnik pH zosta\u0142 przetestowany w warunkach przep\u0142ywowych, dzi\u0119ki dedykowanej celce przep\u0142ywowej opracowanej we wsp\u00f3\u0142pracy z Politechnik\u0105 Wroc\u0142awsk\u0105 w ramach umowy nr 14\/ZP\/2025. Badania te potwierdzi\u0142y dzia\u0142anie opracowanych w ramach projektu miniaturowych czujnik\u00f3w pH w warunkach przep\u0142ywu, co jest kolejnym krokiem w kierunku translacji opracowanego rozwi\u0105zania do zastosowania klinicznego.&nbsp;<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"527\" height=\"400\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-7.png\" alt=\"\" class=\"wp-image-2936 size-full\"\/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Pa\u017adziernik 2025<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Od komponent\u00f3w do integracji \u2013 czujnik pH gotowy do dalszych test\u00f3w<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Zintegrowanie miniaturowej elektrody pH z miniaturow\u0105 elektrod\u0105 odniesienia w jeden uk\u0142ad pomiarowy stanowi kolejny krok milowy w realizacji projektu. Zaprojektowali\u015bmy i wykonali\u015bmy kompaktowy, funkcjonalny czujnik pH z my\u015bl\u0105 o wsparciu diagnostyki i monitorowania pacjent\u00f3w z wt\u00f3rnym zapaleniem otrzewnej.&nbsp;<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"649\" height=\"235\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-8.png\" alt=\"\" class=\"wp-image-2937 size-full\"\/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Byli\u015bmy obecni podczas&nbsp;<strong>15. Forum Rozwoju Mazowsza<\/strong>, gdzie mogli\u015bmy zaprezentowa\u0107 dotychczasowe osi\u0105gni\u0119cia uzyskane w naszym projekcie. Wi\u0119cej informacji pod adresem:&nbsp;<a href=\"https:\/\/www.ibib.waw.pl\/pl\/1394-15forum-mazowsza\">https:\/\/www.ibib.waw.pl\/pl\/1394-15forum-mazowsza<\/a><\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"722\" height=\"1024\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-9-722x1024.png\" alt=\"\" class=\"wp-image-2938 size-full\"\/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Wrzesie\u0144 2025<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Od bada\u0144 laboratoryjnych do realnych potrzeb klinicznych<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Wyniki bada\u0144dotycz\u0105ce wp\u0142ywu niespecyficznej adsorpcji sk\u0142adnik\u00f3w p\u0142yn\u00f3w drena\u017cowych zosta\u0142y zaprezentowane podczas konferencji EUROSENSORS XXXVII (7\u201310 wrze\u015bnia 2025 r.). Na plakacie pt.<em>&nbsp;\u201eDirect-printed, solid-contact pH sensor for clinical applications: Challenges of non-specific adsorption\u201d<\/em>&nbsp;zaprezentowano zaawansowanie technologii oraz \u015bwiadomo\u015b\u0107 wyzwa\u0144 klinicznych.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"724\" height=\"1024\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-10-724x1024.png\" alt=\"\" class=\"wp-image-2939 size-full\"\/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Zesp\u00f3\u0142 projektowy z IBIB PAN zosta\u0142 zaproszony na spotkanie networkingowe z klinicystami, kt\u00f3re zosta\u0142o zorganizowane przez prof. dr hab. n. med. Jaros\u0142awa Kobiel\u0119, ordynatora Kliniki Chirurgii Onkologicznej, Transplantacyjnej i Og\u00f3lnej Uniwersyteckiego Centrum Klinicznego w Gda\u0144sku. Spotkanie, kt\u00f3re odby\u0142o si\u0119 w dniach 24-26 wrze\u015bnia 2025 r. wzmocni\u0142o dialog pomi\u0119dzy in\u017cynierami, a lekarzami, oraz pozwoli\u0142o na zidentyfikowanie scenariuszy przysz\u0142ych zastosowa\u0144 w praktyce klinicznej narz\u0119dzi opracowywanych w IBIB PAN w ramach realizowanego projektu. Wi\u0119cej informacji o wydarzeniu pod adresami:<br>\u2022&nbsp;<a href=\"https:\/\/www.ibib.waw.pl\/pl\/1392-ibib-pan-rozwija-innowacje-dla-chirurgii\">https:\/\/www.ibib.waw.pl\/pl\/1392-ibib-pan-rozwija-innowacje-dla-chirurgii<\/a><br>\u2022&nbsp;<a href=\"https:\/\/kkcotio.gumed.edu.pl\/86507.html\">https:\/\/kkcotio.gumed.edu.pl\/86507.html<\/a>&nbsp;<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"343\" height=\"457\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-11.png\" alt=\"\" class=\"wp-image-2940 size-full\"\/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Lipiec 2025<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Nowa miniaturowa elektroda odniesienia i zielone \u015bwiat\u0142o dla bada\u0144 z wykorzystaniem p\u0142yn\u00f3w drena\u017cowych od pacjent\u00f3w z WZO<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Opracowali\u015bmy now\u0105, miniaturow\u0105 elektrod\u0119 odniesienia wykonan\u0105 w technologii druku bezpo\u015bredniego, pozbawion\u0105 elektrolitu wewn\u0119trznego. To kolejny wa\u017cny krok w udoskonaleniu miniaturowego czujnika pH.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"319\" height=\"256\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-12.png\" alt=\"\" class=\"wp-image-2941 size-full\"\/><\/figure><\/div>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Uzyskali\u015bmy pozytywn\u0105 opini\u0119 Komisji Bioetycznej przy Gda\u0144skim Uniwersytecie Medycznym (nr KB\/343\/2025). Umo\u017cliwi to zespo\u0142owi projektowemu prowadzenie bada\u0144 z wykorzystaniem pr\u00f3bek p\u0142yn\u00f3w drena\u017cowych pochodz\u0105cych od pacjent\u00f3w z wt\u00f3rnym zapaleniem otrzewnej (WZO). Jest to r\u00f3wnie\u017c wa\u017cny krok w stron\u0119 zastosowania wynik\u00f3w bada\u0144 uzyskanych w ramach projektu w praktyce klinicznej.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"337\" height=\"260\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-13.png\" alt=\"\" class=\"wp-image-2942 size-full\"\/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Czerwiec 2025<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Rezultaty prac badawczo-rozwojowych projektu finansowanego przez ABM na konferencji mi\u0119dzynarodowej<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Pierwsze rezultaty naszych bada\u0144 zosta\u0142y zaprezentowane podczas mi\u0119dzynarodowej konferencji NBC 2025 &amp; PCBBE 2025 (16\u201318 czerwca 2025 r.) w ramach wyst\u0105pienia pt. \u201e<em>Direct printed potentiometric sensors for pH monitoring in body fluids\u201d<\/em>.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"724\" height=\"1024\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-14-724x1024.png\" alt=\"\" class=\"wp-image-2943 size-full\"\/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Maj 2025<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Zminiaturyzowane elektrody czu\u0142e na zmiany pH wykonane z wykorzystaniem technologii druku bezpo\u015bredniego<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Zesp\u00f3\u0142 projektowy opracowa\u0142 innowacyjn\u0105, zminiaturyzowan\u0105 elektrod\u0119 pH wykonan\u0105 w technologii druku bezpo\u015bredniego. Rozwi\u0105zanie to otwiera drog\u0119 do tworzenia kompaktowych, elastycznych i \u0142atwych do integracji czujnik\u00f3w jonoselektywnych, zaprojektowanych z my\u015bl\u0105 o nowoczesnych zastosowaniach biomedycznych i klinicznych.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"439\" height=\"352\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-15.png\" alt=\"\" class=\"wp-image-2944 size-full\"\/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Marzec 2025<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Podpisanie umowy na realizacj\u0119 projektu<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>W marcu 2025 r. podpisano umow\u0119 na realizacj\u0119 projektu: System ci\u0105g\u0142ego monitorowania p\u0142yn\u00f3w drena\u017cowych do oceny post\u0119p\u00f3w leczenia chorych z wt\u00f3rnym, bakteryjnym zapaleniem otrzewnej finansowanego przez Agencj\u0119 Bada\u0144 Medycznych w ramach Rz\u0105dowego Planu Rozwoju Sektora Biomedycznego na lata 2022\u20132031. Ca\u0142kowita warto\u015b\u0107 dofinansowania wynosi 4 815 100 PLN. Nr umowy: KPOD.07.07-IW.07-0115\/24.&nbsp;<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1018\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-16-1024x1018.png\" alt=\"\" class=\"wp-image-2945 size-full\"\/><\/figure><\/div>\n\n\n\n<h4 class=\"wp-block-heading\"><strong>Luty 2025<\/strong><\/h4>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Decyzja ABM o finansowaniu projektu<\/strong><\/h3>\n\n\n\n<div class=\"wp-block-media-text has-media-on-the-right is-stacked-on-mobile\"><div class=\"wp-block-media-text__content\">\n<p>Projekt \u201eSystem ci\u0105g\u0142ego monitorowania p\u0142yn\u00f3w drena\u017cowych do oceny post\u0119p\u00f3w leczenia chorych z wt\u00f3rnym, bakteryjnym zapaleniem otrzewnej\u201d uzyska\u0142 dofinansowanie Agencji Bada\u0144 Medycznych w ramach konkursu na realizacj\u0119 bada\u0144 o charakterze aplikacyjnym. Projekt znalaz\u0142 si\u0119 na li\u015bcie rankingowej naboru ABM 2024.<br>Kwota uzyskana na ten cel to 4 815 100 PLN.<\/p>\n<\/div><figure class=\"wp-block-media-text__media\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"1018\" src=\"https:\/\/ibib.waw.pl\/wp-content\/uploads\/2026\/03\/image-17-1024x1018.png\" alt=\"\" class=\"wp-image-2946 size-full\"\/><\/figure><\/div>\n\n\n\n<p>Lista rankingowa:&nbsp;<a href=\"https:\/\/abm.gov.pl\/pl\/konkursy\/archiwalne-nabory-1\/2024\/2634,Konkurs-dla-jednostek-naukowych-na-realizacje-badan-o-charakterze-aplikacyjnym-w.html\" target=\"_blank\" rel=\"noreferrer noopener\">https:\/\/abm.gov.pl\/pl\/konkursy\/archiwalne-nabory-1\/2024\/2634,Konkurs-dla-jednostek-naukowych-na-realizacje-badan-o-charakterze-aplikacyjnym-w.html<\/a><\/p>\n\n\n\n<h3 class=\"wp-block-heading\"><strong>Kontakt:<\/strong><\/h3>\n\n\n\n<p>abm.drain2025(at)ibib.waw.pl<br>murbanowicz(at)ibib.waw.pl<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Cel projektu Opracowanie innowacyjnego, miniaturowego czujnika pH, zintegrowanego z drenem, umo\u017cliwiaj\u0105cego ci\u0105g\u0142\u0105 ocen\u0119 post\u0119p\u00f3w leczenia pacjent\u00f3w z wt\u00f3rnym zapaleniem otrzewnej (WZO). Znaczenie problemu Otrzewna to najwi\u0119ksza b\u0142ona surowicza w organizmie cz\u0142owieka, wy\u015bcielaj\u0105ca jam\u0119 brzuszn\u0105 oraz jam\u0119 miednicy. Stan zapalny otrzewnej powstaje w wyniku przedostania si\u0119 bakterii lub niezaka\u017conego p\u0142ynu ustrojowego do jamy otrzewnej. Najcz\u0119stszym rodzajem [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":0,"parent":847,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"","meta":{"_acf_changed":false,"_only_polish":false,"footnotes":""},"folder":[29],"class_list":["post-2914","page","type-page","status-publish","hentry"],"acf":[],"_links":{"self":[{"href":"https:\/\/ibib.waw.pl\/en\/wp-json\/wp\/v2\/pages\/2914","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/ibib.waw.pl\/en\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/ibib.waw.pl\/en\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/ibib.waw.pl\/en\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/ibib.waw.pl\/en\/wp-json\/wp\/v2\/comments?post=2914"}],"version-history":[{"count":8,"href":"https:\/\/ibib.waw.pl\/en\/wp-json\/wp\/v2\/pages\/2914\/revisions"}],"predecessor-version":[{"id":3176,"href":"https:\/\/ibib.waw.pl\/en\/wp-json\/wp\/v2\/pages\/2914\/revisions\/3176"}],"up":[{"embeddable":true,"href":"https:\/\/ibib.waw.pl\/en\/wp-json\/wp\/v2\/pages\/847"}],"wp:attachment":[{"href":"https:\/\/ibib.waw.pl\/en\/wp-json\/wp\/v2\/media?parent=2914"}],"wp:term":[{"taxonomy":"folder","embeddable":true,"href":"https:\/\/ibib.waw.pl\/en\/wp-json\/wp\/v2\/folder?post=2914"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}